Checked against the Marketing Discipline Guidelines 2024 (Ver. 1, effective 24.10.2024) on 24 November 2026. Published by MDG Services on 24 November 2026.
What MDG says
| Question | What MDG says | Clause |
|---|---|---|
| Sales from the tank being filled | Stop before decantation begins and stay stopped until it is complete | MDG 1.2(vii) |
| Sales from other tanks or products | Not mentioned | none |
| After decanting | At least 50 litres through the pump, then the nozzle sample for the density record | MDG 1.2(xiv) |
MDG does not say where those 50 litres go or how long the tank waits before it sells again.
Reading it literally
MDG's stop is tied to "the concerned underground tank", not to the whole outlet or to a particular dispensing unit MDG 1.2(vii). So MDG neither allows nor bars sales from the other tanks while a lorry unloads. That silence is not a permission: other rules can still apply.
What else may limit selling
The dealer must also follow the statutory rules on storage and sale of petroleum products MDG 1.5(i), PESO rules MDG 1.5(ii) and the oil company's instructions MDG 1.5(v). MDG does not list what they say about selling during unloading. Confirm with your oil company what applies at your outlet.
General practice, not an MDG rule: keep customer vehicles clear of the lorry, the hose and the tank's fill point while product is flowing.
An example
For example (a made-up outlet with one petrol tank and one diesel tank): a petrol lorry arrives. Sales from the petrol tank stop before decantation and stay stopped until it is complete MDG 1.2(vii). MDG says nothing about the diesel nozzles, so the dealer asks the oil company whether diesel sales may continue. After decanting, 50 litres go through the pump before the density sample MDG 1.2(xiv).
Questions dealers ask
01Can the other pumps keep selling while a tanker is unloading?
MDG stops only sales from the underground tank that is being filled MDG 1.2(vii). It says nothing about other tanks or products, so confirm with your oil company what PESO rules and company instructions allow MDG 1.5(ii) MDG 1.5(v).
02When can sales from the tank restart after unloading?
MDG says sales stay stopped until decantation is complete MDG 1.2(vii). It then asks for at least 50 litres through the pump before the density sample MDG 1.2(xiv), and does not say where those litres go or give a waiting time.
03Which rules besides MDG apply during unloading?
The dealer must follow the statutory rules on storage and sale of petroleum products MDG 1.5(i), PESO rules MDG 1.5(ii) and the oil company's instructions MDG 1.5(v). MDG does not list what they say about selling.
04Is there a penalty for selling from a tank while it is being filled?
Chapter 5 does not list it as an irregularity. For anything not listed, the oil company's competent authority acts after an enquiry, in line with natural justice MDG 8.5.4, and an irregularity must be established first MDG 8.5.2.
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).
Related pages
About Dealer Kavach (advertisement)
Dealer Kavach is an app from MDG Services that tracks your outlet's filings, renewals, inspections and daily reports, and reminds you before deadlines, in Hindi and English.