The morning routine
| When | What is done and written down | Clause |
|---|---|---|
| Before the first sale | A nozzle sample; its density at 15°C goes in the density register. Latest time: 10 AM | MDG 1.4.1(c) MDG 5.1.9 |
| In the morning | Pump meter readings, and the product dip and water dip of each tank, taken separately. The water dip is part of the daily stock register | MDG 1.3 MDG 1.4.1(b) |
| Daily | The Weights & Measures seal on each metering unit and totaliser, and that the unit's certificate is valid. A tampered seal stops sales on that unit | MDG 1.4.2(a) |
| Daily, before sales | Every nozzle tested for correct delivery; the quantity used for the test goes in the stock register. See the 5-litre test | MDG 1.4.2(d) |
| Daily | A look for leaks in the pump, hose and nozzle; a leak is reported to the oil company at once | MDG 1.4.2(e) |
| Daily | The toilet checks, with the maintenance sheet kept and displayed | MDG 5.1.14(b) |
| Before every delivery | The meter at zero, shown to the customer | MDG 1.4.2(f) |
MDG gives an hour only for the density. For the others it says "daily", "in the morning" or "before sales". General practice, not an MDG rule: follow one fixed order each morning, so no check is skipped.
What the inspector asks for
Before 10 AM, the inspector asks for the previous morning's reading, or the after-tanker reading if a load came the previous day. After 10 AM, it is this morning's reading, or the one taken after today's unloading if a load has already arrived MDG 5.1.9. What a missing figure costs: the 10 AM rule.
For example (a made-up outlet): a tanker is unloaded at 6:30 PM on Monday. An inspector arrives at 8 AM on Tuesday. The figure that must exist is the one taken after Monday's unloading MDG 5.1.9.
Records and their periods: records to keep. The evening before: what to lay out.
Questions dealers ask
01Which checks must be done and recorded when a petrol pump opens in the morning?
The nozzle density at 15°C before sales, the meter readings, the product and water dip of each tank, the seal, nozzle and leak checks, and the toilet check MDG 1.4.1(c) MDG 1.3 MDG 1.4.2(a) MDG 1.4.2(d) MDG 1.4.2(e) MDG 5.1.14(b).
02Do all the morning checks have to be finished by 10 AM?
MDG gives 10 AM only for the morning density MDG 5.1.9. The other checks are daily or before sales start, with no hour fixed MDG 1.4.2(a) MDG 1.4.2(d).
03What if a morning check finds water, a tampered seal or a wrong nozzle delivery?
Water: report it at once to the controlling company office MDG 1.4.1(b). A tampered seal: stop sales through that unit and report it at once MDG 1.4.2(a). A wrong delivery: tell the Weights & Measures Department and the oil company, and do not run the unit until it is re-stamped and the delivery is set right MDG 1.4.2(d).
04Is a missing morning density a major or minor irregularity?
Major, if the figure is missing when the inspector arrives MDG 5.1.9 MDG 8.3. See the 10 AM rule for what follows.