Checked against the Marketing Discipline Guidelines 2024 (Ver. 1, effective 24.10.2024) on 24 November 2026. Published by MDG Services on 24 November 2026.
What happens, moment by moment
| Moment | What is compared | What MDG says |
|---|---|---|
| Tanker arrives, before decanting | Each compartment's 15°C reading against the invoice density | Within ±3.0 kg/m³ MDG 1.2(iv). If you doubt the quality, contact the supply location or the Area Field Officer MDG 1.2(ix) |
| An inspector's density test fails | The officer's reading against the reference density in your register MDG 2.10 MDG Annexure 4 | An oil company officer suspends sales and supplies of all products; samples go for testing on priority MDG 2.5(K) |
| Mobile lab visit | The officer's reading against your tank density after the last receipt | A printed maximum variation of 3.0 kg/m³ MDG Annexure 12a MDG Annexure 13a. Failing density or any clinical test is acted on as established adulteration, with sales and supplies suspended MDG 7.4 Note (i) MDG 7.4 Note (ii) |
A missing reference density has its own rule: reference density MDG 5.1.9.
Established adulteration is critical, with termination at the first instance MDG 8.2.
See when a sample fails and the mobile lab page.
The lab's ranges
At 15°C: petrol 720–775 kg/m³, diesel up to B7 810–845, and B8 to B20 blends 820–860 MDG 7.6. The density range page has the footnotes.
What MDG does not say
- A tolerance for your own morning reading. It asks only that you record it MDG 1.4.1(c).
- What counts as a "density failure" at an inspection. Apart from the mobile lab form, MDG prints no figure for it.
- Whether a variation above 3.0 is a failure by itself, or what to do with a tanker outside ±3.0 beyond calling. Ask your oil company.
An example
For example (a made-up outlet): the invoice shows 743.0 kg/m³ and the 15°C reading is 747.0, which is 4.0 away. The manager doubts the quality and calls the supply location MDG 1.2(ix). A mobile lab later reads 746.0 against the tank figure of 744.5 recorded after the last receipt: a variation of 1.5, inside the 3.0 the form prints MDG Annexure 12a.
General information, not legal advice. For your own notice, speak to an advocate or your oil company.
Questions dealers ask
01What if my tanker's density is outside ±3.0 kg/m³ of the invoice?
MDG tells you to contact the supply location or the Area Field Officer if you doubt the quality MDG 1.2(ix). Its retention-sample steps are written for a tanker whose density is within the limit, and it gives no further steps for one outside it MDG 2.3.
02What happens if density fails at an inspection?
An oil company officer suspends sales and supplies of all products, and samples are drawn and sent for testing on priority. Action follows the results MDG 2.5(K).
03How much difference may there be between my tank density and the mobile lab's reading?
The test report form prints a maximum variation of 3.0 kg/m³ MDG Annexure 12a MDG Annexure 13a. MDG does not say separately what follows if it is larger.
04What if a mobile lab finds my density or another test failing?
A failure in density or any clinical test is acted on as established adulteration, and the mobile lab suspends sales and supplies MDG 7.4 Note (i) MDG 7.4 Note (ii).
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).
Related pages
More from MDG Services: the petrol pump guide
About Dealer Kavach (advertisement)
Dealer Kavach is an app from MDG Services that tracks your outlet's filings, renewals, inspections and daily reports, and reminds you before deadlines, in Hindi and English.