Checked against the Marketing Discipline Guidelines 2024 (Ver. 1, effective 24.10.2024) on 24 November 2026. Published by MDG Services on 24 November 2026.
Receiving it, step by step
The order is that of receiving a tanker, applied one compartment at a time.
- Match the invoice. The number of compartments, and the product and quantity in each MDG 1.1(iii).
- Dip and water-test every compartment, and stop sales from the underground tank that will receive the product MDG 1.2(vii).
- Density, compartment by compartment. At each manifold run off about 20 litres, then read and record that compartment's density and temperature on its own. Each 15°C figure is compared with the invoice density, within ±3.0 kg/m³ MDG 1.2(iv) MDG 1.2(viii). See invoice density check.
- Retention samples. Once density is within the limit, draw bottom composites in proportion to the quantity received in each compartment, after removing at least 20 litres from each: 2 × 1 litre of MS and/or 1 × 1 litre of HSD. The driver and you both sign the label MDG 1.2(x) MDG 2.3. See retention samples.
- Decant each product into its correct underground tank MDG 1.2(xi). If a product has more than one tank, the tank number goes on the sample container MDG 2.3.
- After decanting, run at least 50 litres through the pump and record the 15°C density, kept for each tank and product MDG 1.2(xiv) MDG Annexure 1.
An example
An illustration with made-up figures:
| Compartment | Product on the invoice | Quantity | Goes into |
|---|---|---|---|
| 1 | Petrol | 6,000 litres | Petrol tank |
| 2 | Petrol | 6,000 litres | Petrol tank |
| 3 | Diesel | 8,000 litres | Diesel tank |
Each compartment gets its own dip, water test and density reading. The two petrol compartments together make up the MS samples, and the diesel compartment the HSD sample MDG 2.3.
What MDG says about mixed loads, and what it leaves out
MDG bars mixed loads in tank lorries with a common manifold. That is a supply location rule, not a dealer check MDG 3.1(j), and MDG does not say what a dealer does if such a lorry arrives.
MDG leaves two points open:
- Whether sales from the first tank may restart before the whole lorry is empty. It says sales from the concerned tank stop until decantation is complete MDG 1.2(vii). See selling during unloading.
- Which invoice figure a compartment is compared with when the lorry carries two products. General practice, not an MDG rule: use the density printed for that compartment's product.
Ask your oil company about both.
Questions dealers ask
01How do I unload a tanker that carries both petrol and diesel?
Treat each compartment as its own check: match product and quantity MDG 1.1(iii), dip and water-test it MDG 1.2(vii), read its density and temperature on its own sample MDG 1.2(viii), then decant each product into its correct underground tank MDG 1.2(xi).
02Does MDG allow petrol and diesel in the same tanker?
MDG's receipt rules cover it: they ask for the product and quantity in each compartment MDG 1.1(iii) and for MS and/or HSD samples MDG 2.3. Mixed loads are barred in lorries with a common manifold, a duty of the supply location MDG 3.1(j).
03How many retention samples does a lorry with two products need?
2 × 1 litre of MS and 1 × 1 litre of HSD, as bottom composites in proportion to the quantity in each compartment MDG 2.3.
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).
Related pages
About Dealer Kavach (advertisement)
Dealer Kavach is an app from MDG Services that tracks your outlet's filings, renewals, inspections and daily reports, and reminds you before deadlines, in Hindi and English.