Checked against the Marketing Discipline Guidelines 2024 (Ver. 1, effective 24.10.2024) on 24 November 2026. Published by MDG Services on 24 November 2026.
Who stops, and when
| What is found | What stops | Clause |
|---|---|---|
| Short beyond the legal limit, W&M seals intact | Sales through that unit. In a dual DU or MPD, through that nozzle. Recalibrate and re-stamp before sales restart | MDG 5.1.2(a) |
| Inside the band MDG prints, ±10 ml to ±25 ml per 5 litres, seals intact | Nothing at first: it is recorded. Recalibrate and re-stamp within 15 days of the observation, or that unit or nozzle stops | MDG 5.1.2(a) |
| A variation in the dealer's own morning nozzle test | The dealer does not operate the dispensing unit until it is re-stamped and the delivery is right | MDG 1.4.2(d) |
| A seal missing, different or with a broken wire; a tampered totalizer; an unauthorised fitting or part change | The whole unit stops and is sealed, and samples of all products go to the lab | MDG 5.1.2(b) MDG 5.1.3 MDG 5.1.4 |
MDG points to the permissible limits in the Legal Metrology Act, 2009 and its Rules MDG 5.1.2(a). It prints only the band above.
What the dealer does
- Tell W&M and the controlling oil company office at once MDG 1.4.2(d).
- Arrange recalibration with the W&M inspector: the dealer or the company's maintenance representative does this MDG 4.3(a). W&M does the re-stamping MDG 1.4.2(d).
- Do not operate the unit until it is re-stamped and the delivery is right MDG 1.4.2(d).
The daily test is on the 5 litre test page.
Two wordings MDG leaves open
The daily-test rule keeps the dispensing unit off MDG 1.4.2(d). The short-delivery rule names the nozzle for a dual DU or MPD MDG 5.1.2(a). MDG defines neither term and does not say which wording governs a variation the dealer finds himself. Ask your oil company which applies to your unit. General practice, not an MDG rule: ask in writing and keep the reply.
What it costs
Short delivery with the seals intact is a minor irregularity MDG 8.4(iii)(h). The amounts are on the 5 litre test page and in penalty classes. Tampered seals, a tampered totalizer and unauthorised fittings are critical MDG 8.2: see W&M and totalizer seals and first steps for a broken seal.
Questions dealers ask
01If one nozzle delivers short, does the whole dispenser have to stop?
Under the short-delivery clause, sales stop through the concerned unit, or through the nozzle alone in a dual DU or MPD MDG 5.1.2(a). The daily-test clause speaks of the dispensing unit MDG 1.4.2(d), so confirm with your oil company.
02Can a nozzle keep selling if it is only slightly short?
If it is found within ±10 ml to ±25 ml per 5 litres, sales continue and the finding is recorded. Recalibration and re-stamping fall due within 15 days, or that unit or nozzle stops MDG 5.1.2(a).
03When does the whole dispenser stop, not just one nozzle?
When a seal or the totalizer is tampered, or a fitting or part is added, removed or changed. The unit is sealed and samples of all products go to the lab MDG 5.1.2(b) MDG 5.1.3 MDG 5.1.4.
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).
Related pages
About Dealer Kavach (advertisement)
Dealer Kavach is an app from MDG Services that tracks your outlet's filings, renewals, inspections and daily reports, and reminds you before deadlines, in Hindi and English.