Invoice has no density (or tank number) written on it: what to do before unloading

Short answer

Under the Marketing Discipline Guidelines 2024 (MDG 2024), the supply location must write the 15°C density, the filling point, the tank number and the release time on the invoice, and your receipt check is made against that density, within ±3.0 kg/m³ MDG 2.2.1(iv) MDG 3.1(h) MDG 1.1(v) MDG 1.2(iv). MDG does not say what to do when the figure is missing and names no substitute. If you doubt the quality, contact the supply location or the Area Field Officer MDG 1.2(ix).

The Marketing Discipline Guidelines 2024 (MDG 2024) are the oil companies' rules for their dealers, and bind dealers through the dealership agreement. This page is a plain-language explanation by MDG Services (a brand of VRUOOM Private Limited). It is not the official text and is not connected with or approved by IndianOil, BPCL, HPCL or any government body, so please check the current guidelines and circulars on the oil companies' own websites and with your oil company officer before you act.

Checked against the Marketing Discipline Guidelines 2024 (Ver. 1, effective 24.10.2024) on 24 November 2026. Published by MDG Services on 24 November 2026.

What the invoice should carry

The supply location gives the density at 15°C, the filling point, the storage tank number and the release time on the invoice MDG 2.2.1(iv). The density it observed goes on every lorry's invoice with the tank number MDG 3.1(h). On arrival you match the invoice details, the recorded density among them, with the lorry MDG 1.1(v). For the full receipt check, see receiving a tanker.

Before you unload

MDG prints no steps for a missing figure. These are the clauses that bear on it, in the order a dealer meets them:

  1. Spot the gap at the receipt check MDG 1.1(v).
  2. Know the benchmark. Your 15°C reading is checked against the invoice density, within ±3.0 kg/m³ MDG 1.2(iv): see the invoice density check. Until decanting, the reference density is the figure in the dispatch document MDG 2.10.
  3. If you doubt the quality, contact the supply location or the Area Field Officer MDG 1.2(ix).
  4. General practice, not an MDG rule: ask the supply location to confirm the density and tank number in writing before you unload, and note who confirmed and when.
  5. Take your own readings as usual. Each compartment's density and temperature are recorded MDG 1.2(viii).

After decanting, your own reading becomes the reference. Take it once at least 50 litres have gone through the pump MDG 1.2(xiv) MDG 2.10. See the reference density rule.

What MDG does not say

  • Which figure to use when the invoice has no density, since it names no substitute.
  • Whether you may unload while you wait for confirmation, or should hold the lorry back.
  • What happens when the tank number is missing. Ask your oil company about all three.

An example

For example (a made-up outlet): a tanker arrives with an invoice that shows the tank number and release time but no density. The manager asks the supply location for the 15°C density in writing, a practice step MDG does not set, notes who gave it and when, and takes each compartment's reading MDG 1.2(viii).

Questions dealers ask

01What should I do if the invoice has no density?

MDG does not say, and it names no substitute figure. If you doubt the quality, contact the supply location or the Area Field Officer MDG 1.2(ix). General practice, not an MDG rule: ask the supply location to confirm the density in writing before you unload.

02Whose job is it to write the density on the invoice?

The supply location's. It records the 15°C density, filling point, tank number and release time on the invoice MDG 2.2.1(iv) MDG 3.1(h).

03Which density counts as the reference until the tanker is decanted?

The one recorded in the dispatch document MDG 2.10. MDG does not say what counts when that document carries no figure.

04Do I still record my own compartment readings?

Yes. Each compartment's sample is checked for density and temperature and recorded in the register MDG 1.2(viii).

05Why does the tank number on the invoice matter?

The lab compares your sample with the supply location sample from the tank named on the delivery documents MDG 2.4.1 MDG 2.4.2. MDG does not say what to do when the invoice names no tank.

Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).

Related pages

Tanker density check against the invoice density, step by stepHow to check a tanker's petrol or diesel against the density on the invoice: sample every compartment, convert to 15°C, stay within ±3.0 kg/m³.
Tanker decantation at a petrol pump: the MDG 2024 checklistHow a dealer receives and decants a tank lorry under the Marketing Discipline Guidelines 2024: 14 steps, from matching the invoice to recording density.
Morning density by 10 AM: the reference density ruleMDG 2024 makes a dealer record density by 10 AM each morning and after every tanker: which figure an inspector asks for, and what a miss costs.
Oil company duties under MDG: what a dealer can expectWhat MDG 2024 requires of the oil company: depot quality checks, water dips, 30-day samples, invoice details, tanker checks, GPS, sample kit, training.

More from MDG Services: the petrol pump guide

Petrol pump guide for IndiaOpen, license and run a pump: nine topics, every fact with its official source and date.
How to open a petrol pump in IndiaThe route through the oil companies: who can apply and how a dealer is chosen.
Licences and NOCs a petrol pump needsPESO, pollution consent, fire and more, and who gives each one.
How a petrol pump works: tanks and dispensersTanks, dispensers, nozzles and vapour recovery, and how each is checked.

About Dealer Kavach (advertisement)

Dealer Kavach is an app from MDG Services that tracks your outlet's filings, renewals, inspections and daily reports, and reminds you before deadlines, in Hindi and English.

About this page. This page is a plain-language explanation published by MDG Services, a brand of VRUOOM PRIVATE LIMITED (CIN U29194HR2021PTC098450). It is general information, offered free of charge. It is not the official text of any rule.

Not connected with the oil companies or the government. MDG Services is a private company. It is not connected with, approved by, endorsed by, or acting for Indian Oil Corporation Limited (IndianOil), Bharat Petroleum Corporation Limited (BPCL), Hindustan Petroleum Corporation Limited (HPCL) or any government body. Our name shares letters with the short form "MDG" that the oil companies use for their Marketing Discipline Guidelines. That does not mean any link with them.

Names and marks. IndianOil, BPCL, HPCL and the names of their documents belong to their owners. We write them only to say whose rules we are explaining.

Check the official source. The Marketing Discipline Guidelines 2024 (Ver. 1, effective 24.10.2024) and related circulars are issued by the oil companies. Rules, amounts and dates can change, and amendments may reach dealers directly without being public. Before you act, read the current documents on the oil companies' own websites (iocl.com, bharatpetroleum.in, hindustanpetroleum.com) and ask your own oil company's officer. If this page and the official document differ, the official document is the one to follow.

What the amounts mean. Amounts in the guidelines are the minimum action. The oil company may take higher action, up to ending the dealership. Do not treat any amount shown here as your full exposure.

Court and Parliament items. Where we mention a court order or a statement in Parliament, we report what was said on the date shown. It is not the rule for your outlet, and the position may have changed since. Your dealership agreement and the oil company's current guidelines decide.

Not legal advice. This is general information, not legal advice. For your own notice, reply or appeal, speak to an advocate or your oil company. Examples use made-up outlets.

Last checked. The "checked" date shows the day we last compared this page with the official documents. It does not promise that nothing has changed since.

Report an error or send a legal notice. If you see a mistake, or need to send us a notice, write to hello@mdgservices.in. We read every message, check it, and correct or remove the page.

Limits on our responsibility. We take reasonable care to keep this page accurate. To the extent the law allows, MDG Services and VRUOOM PRIVATE LIMITED are not responsible for loss caused by relying on this page alone instead of the official documents. This does not limit anything the law does not allow us to limit, including responsibility for fraud or for an error we knew about and did not correct. Your legal rights are not affected.

Advertisement. The box headed "About Dealer Kavach" and the part marked "Advertisement" about Kavach Shuruaat are advertisements for paid services from MDG Services. This explanation is free and needs no sign-up or purchase to read.

Hindi pages. Hindi pages are written for easy reading. If a Hindi page and the official English document differ, the official English document is the one to follow.

Full disclaimer

Report an error or send a legal notice: hello@mdgservices.in