What is tracked tank by tank
| Record | What it carries for each tank | Clause |
|---|---|---|
| Your tank lorry sample | The tank that received the load, written on the container; the Annexure 3 label has a line for it. You keep the last two loads of each tank | MDG 2.3 MDG 2.9.2 MDG Annexure 3 |
| Your density record | The Annexure 1 format is headed by tank number, product and month | MDG Annexure 1 |
| The inspector's samples | Taken from the nozzles of units on all tanks: 6 x 1 litre per petrol tank, 3 x 1 litre per diesel tank | MDG 2.2.2.2 MDG 2.4.1 MDG 2.4.2 |
| The inspector's label | The dispensing unit number and the tank number | MDG Annexure 4 |
Steps on a tank lorry: the tank lorry retention sample. The record itself: the density register.
What reaches the lab for each tank
The three kinds of sample the lab gets are on what the inspector takes. Two things depend on the tank:
- Your lorry samples used are those of the tank joined to the unit he sampled MDG 2.4.1(ii) MDG 2.4.2(ii).
- If your tanks last received product on different days, the depot's reference sample for each of those supplies is needed MDG 2.4.1(iii) MDG 2.4.2(iii).
That is why the tank number on your containers and records must be right.
For example (a made-up outlet): two petrol tanks and two diesel tanks. An inspector draws 6 + 6 + 3 + 3 = 18 samples, and you keep 2 + 2 + 1 + 1 = 6 MDG 2.4.1 MDG 2.4.2. Your own lorry samples are 4 containers per petrol tank and 2 per diesel tank, 12 in all MDG 2.3 MDG 2.9.2.
What MDG does not say
The Annexure 1 format is headed by tank number MDG Annexure 1, but MDG's morning density clause says only "from the pump nozzle" MDG 1.4.1(c). It does not say which nozzle serves which tank. General practice, not an MDG rule: write the tank number beside each reading, use a unit joined to the tank that received the load for the after-delivery reading, and ask your oil company if unsure.
Questions dealers ask
01What if one fuel has two tanks: how do I keep samples and density records?
Mark the tank number on each tank lorry sample and keep the last two loads of each tank MDG 2.3 MDG 2.9.2. Keep the density record with its tank number and product MDG Annexure 1.
02How many sample containers do I keep with two petrol tanks?
For the last two loads of each tank, 4 x 1 litre per tank, so 8 in all MDG 2.3 MDG 2.9.2. For two diesel tanks it is 2 per tank, 4 in all.
03Does the inspector sample both tanks?
Yes. Samples are drawn from the nozzles of units on all tanks of both petrol and diesel MDG 2.2.2.2.
04Which of my lorry samples go to the lab?
Those of the tank joined to the unit the inspector sampled MDG 2.4.1(ii) MDG 2.4.2(ii).
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).