Checked against the Marketing Discipline Guidelines 2024 (Ver. 1, effective 24.10.2024) on 24 November 2026. Published by MDG Services on 24 November 2026.
What the label records
MDG makes the people drawing the sample responsible for checking the container before and after filling, and for correct labelling and sealing with the right seal number MDG 2.5(A). In practice, read every line before you sign.
| Line on the Annexure 4 label MDG Annexure 4 | What to check |
|---|---|
| Outlet, oil company, product, date and time | Your outlet; MS or HSD as drawn; right date and time |
| Dispensing unit and tank number | The unit and tank really sampled |
| Density at 15°C | Two figures: yours from the density register, and the officer's reading |
| Date and lorry number of the last receipt in that tank | Match your records |
| Plastic seal numbers | One set for the aluminium container, one for the wooden box; match the seals you see |
| Your signature, name, outlet seal, place and date | Filled by you or your representative |
Both labels carry a statement, signed by you, that the containers were rinsed in your presence with the same product and that you received one of the three sets MDG Annexure 4 MDG Annexure 11. In practice, watch the rinse and have your set in hand before you sign.
A mobile lab uses the Annexure 11 label. It leaves out the density, last-receipt and lorry-number lines and has no outlet-seal line. It adds the mobile lab's reference number MDG Annexure 11 MDG 7.5.
Keeping your set
- Take your set: 2 containers of MS or 1 of HSD for each tank sampled MDG 2.4.1 MDG 2.4.2. The full split is in what the inspector takes.
- Keep it in safe custody MDG Annexure 4, until testing and the steps after it are finished MDG 2.9.2. In practice, leave seals and label untouched.
- If every sample passes, the oil company tells you in writing and the retained samples can be disposed of MDG 2.5(F). If one fails, see what happens when a sample fails for the 10-day re-test request MDG 2.5(H).
For example (a made-up outlet): an officer draws petrol from a unit joined to MS tank 2. The label must show that unit and tank 2, and your containers and box must carry the seal numbers written on it MDG Annexure 4.
What MDG does not say
MDG says only that the set stays in safe custody MDG Annexure 4. It gives no storage method and no steps for a wrong label line. Ask your oil company.
Questions dealers ask
01What do I check on the sample label and how do I keep my sample?
The label records the outlet and product, the unit and tank, both density figures, the date and lorry number of the last receipt, and the seal numbers of the container and the box MDG Annexure 4. Keep your set until testing and the steps after it are over MDG 2.9.2.
02Does the inspector pay for the fuel he takes?
Yes. Officials pay for the samples and get a cash memo MDG 2.2.2.2. A mobile lab pays for the quantity used in testing, and for the retained samples too if one fails. Keep the cash receipts MDG 7.3.1.
03Is the mobile lab's label the same as the inspector's?
No, it is a separate form, Annexure 11, with fewer lines than the inspector's MDG Annexure 11 MDG 7.5.
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).
Related pages
About Dealer Kavach (advertisement)
Dealer Kavach is an app from MDG Services that tracks your outlet's filings, renewals, inspections and daily reports, and reminds you before deadlines, in Hindi and English.