What the depot keeps
| What | Detail | Clause |
|---|---|---|
| Daily sample | At least 4 x 1 litre of MS and 2 x 1 litre of HSD, from the filling point where lorries are loaded | MDG 2.2.1(i) |
| After a tank switch-over | Taken again once the earlier product has flushed out of the pipeline | MDG 2.2.1(ii) |
| Number | Each sample has a traceable number, the location keeps a record, and the number goes in your delivery documents | MDG 2.2.1(iii) MDG 3.1(e) |
| How long | At least 30 days | MDG 2.2.1(iii) MDG 2.9.1 |
How the lab uses it
- The lab tests the depot sample, if within the retention period, with your pump's sample and your tank lorry sample before a decision is taken MDG 2.5(I). How it compares them is on what happens when a sample fails.
- The depot sample used is from the tank named in your delivery documents MDG 2.4.1(iii) MDG 2.4.2(iii).
- If the depot sample was already sent for testing earlier, the lab uses that test report MDG 2024, chapter 2, General Notes (1).
- When a mobile lab sample fails, the supply location is to be told at once by phone so that the depot sample can be retained MDG 2.4.4.
Why a doubt should be raised early
The 30 days is a minimum, and MDG sets no step for a doubt raised after it, apart from the earlier lab report above. It does not say how to ask the depot to hold or test a sample. On receipt of a lorry, a doubt about quality goes to the supply location or the area field officer for instructions MDG 1.2(ix).
For example (made-up dates): a lorry is filled at the depot on 2 March. A doubt raised in the second week of March is well inside the 30 days. One raised in mid-April may find the sample gone.
General practice, not an MDG rule: when you raise a doubt, write down the invoice number, date, lorry number, tank number and product, and send them to your sales officer the same day.
What MDG does not say
MDG does not tell the dealer to raise a doubt within 30 days, and it does not say what the lab compares against when the depot sample has gone and was never tested.
Questions dealers ask
01How long does the depot keep its fuel sample?
At least 30 days MDG 2.2.1(iii) MDG 2.9.1.
02How much does the depot sample each day?
At least 4 x 1 litre of MS and 2 x 1 litre of HSD every day, and again after a storage tank switch-over MDG 2.2.1(i) MDG 2.2.1(ii).
03How do I tie my delivery to its depot sample?
The sample's number is written in your delivery documents MDG 3.1(e). The invoice also carries the density at 15°C, the filling point, the storage tank number and the release time MDG 2.2.1(iv).
04Must I raise a doubt within 30 days?
MDG does not say so. The 30 days is the least the depot must keep its sample MDG 2.9.1.
05What if the depot sample is no longer there?
If it was sent for testing earlier, its lab report is used MDG 2024, chapter 2, General Notes (1). MDG asks for the depot sample to be tested only if it is within the retention period MDG 2.5(I) and says nothing more about one that is gone and was never tested.
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).