What MDG asks
| What | Clause |
|---|---|
| Ensure a power backup, a generator or UPS, for power failure | MDG 1.5(ix) |
| Keep the automation working ("No automation, No Operation") | MDG 1.5(viii) |
| Report any malfunction at once to the authorised official, then act on the direction | MDG 1.5(viii) |
Clause 1.5(viii) speaks of malfunctioning and does not mention power cuts MDG 1.5(viii). MDG prints no steps for a cut. These are the clauses that bear on it, in the order a dealer meets them:
- The backup takes over MDG 1.5(ix).
- If the automation stops anyway, report it at once and follow the direction MDG 1.5(viii).
- If the direction is manual mode, or leaving the ATG off, it needs written permission MDG 5.1.16 Note. Manual mode shows what counts.
General practice, not an MDG rule: note the time the power failed and the time you reported.
If there is no permission
Manual mode, or an ATG left off or not working, without permission is a major irregularity MDG 5.1.16(a) MDG 5.1.16(b) MDG 8.3(vii). The first instance is a penalty of Rs 1,00,000.
The full ladder is on the automated outlets page. MDG lists no separate irregularity for having no backup. For matters it does not list, the oil company acts after an enquiry MDG 8.5.4. See classes of irregularity.
What MDG does not say
- How long the backup must run, or how big it must be.
- Whether sales must stop while mains and backup are both down. Ask your oil company.
An example
For example (a made-up outlet): the mains fails at 6:40 PM and the generator does not start, so the automation stops. The manager calls the authorised official at once MDG 1.5(viii) and asks for any manual mode instruction by email before switching a unit to manual MDG 5.1.16 Note. He notes both times and files the email, which is general practice, not an MDG rule.
General information, not legal advice. For your own notice, speak to an advocate or your oil company.
Questions dealers ask
01What should I do when the power goes at an automated petrol pump?
Have a generator or UPS ready to take over MDG 1.5(ix). If the automation stops working anyway, report it at once to the oil company's authorised official and follow that official's direction MDG 1.5(viii).
02Is a generator or UPS compulsory at an automated pump, and for how long must it run?
Yes, MDG says it must be ensured MDG 1.5(ix). It gives no running time, capacity or fuel stock, so ask your oil company.
03Can I run in manual mode during a power cut?
Only with permission from the competent authority, by email or signed letter from a company official, which you keep MDG 5.1.16(a) MDG 5.1.16 Note. The clause lists no exception for a power cut.
04What is the penalty for manual mode or a switched-off ATG without permission?
It is a major irregularity. The first instance is at least Rs 1,00,000, once the irregularity is established MDG 8.3(vii) MDG 8.5.2. The oil company may take higher action MDG 8.5.1; the full ladder is on the automated outlets page.
Read the official text: Marketing Discipline Guidelines 2024 (PDF on Bharat Petroleum's website) (also published on iocl.com).