Petrol pump layout plan: parts of the site and who approves it

Short answer

A petrol pump's drawing must be approved by PESO before building: the specifications and plans go with the application under rule 131, and PESO returns a signed copy if satisfied Petroleum Rules 2002, rule 131. The site plan must show everything protected within 100 metres Petroleum Rules 2002, rule 131. Nothing on this page replaces the drawing PESO approves. Any later alteration also needs prior written approval Petroleum Rules 2002, rule 146.

MDG Services makes Dealer Kavach, an app for petrol pump dealers, so this page comes from the maker of a product it may mention. It is general information, not legal, tax or financial advice. Rules, fees and guidelines change and differ by oil company and state: every fact here names its source and the date we checked it, so confirm it with the oil company or the authority before you act. We do not sell, allot or arrange dealerships or licences.

Facts checked on 14 November 2026. Published by MDG Services on 16 November 2026.

A pump's layout is a safety drawing first. Under the June 2023 guideline the oil company's office prepares the layouts for statutory approvals Selection brochure June 2023, cl.8(D); PESO approves the plan for your site. Facts are as on 14 November 2026. For plot size and distances, see land for a petrol pump.

What are the parts of the site?

In practice a pump has an approach and exit, a forecourt with canopy, dispenser islands, underground tanks, a sales room, an air and water point, toilets and a clear path for the tanker. The rules name some of these:

ElementRule or condition behind it
Underground tanks, in the positions on the approved planForm XIV, condition 1
Tank filling and dipping pipes, vent pipes, valves, pumpsShown on the plan Petroleum Rules 2002, rule 131
Vent pipe: at least 4 m high and 4 m from adjoining land and from the sales room openingForm XIV, condition 5
Sales room or kioskListed in the licence Form XIV, description of premises
Licence number marked on premisesPetroleum Rules 2002, rule 133

Who approves the drawing, and when?

Before building, you apply with specifications and plans drawn to scale; PESO returns a signed copy if satisfied Petroleum Rules 2002, rule 131. The application is online in Form IX PESO FAQs on Petroleum Rules. See the PESO licence for the whole sequence.

What must the site plan show?

  • The surroundings and all protected works within 100 metres of the edge of the facilities to be licensed Petroleum Rules 2002, rule 131.
  • The position, capacity and elevation of tanks, filling and discharge points, vent pipes and fire-fighting facilities Petroleum Rules 2002, rule 131.
  • Dimensions in metric only, signed by the applicant PESO FAQs on Petroleum Rules.

The application also carries an undertaking that no school, hospital of 10 beds or more, residential area under local law or water body lies within 50 m PESO FAQs on Petroleum Rules. PESO's FAQs name OISD-118 as the OISD practice for layout of oil and gas installations PESO FAQs on Petroleum Rules; whether a standard applies to a pump, ask the oil company. Tank design is in tanks and equipment.

What if the built pump differs from the drawing?

No alteration may be carried out until the licensing authority approves the new drawing in writing; the licence is amended afterwards Petroleum Rules 2002, rule 146. A licence is liable to be cancelled if the premises do not conform to the approved plan Form XIV, conditions of licence.

One drawing counts

Nothing on this page, and no sample drawing, replaces the drawing PESO approves for your site.

Where this comes from

Questions people ask

01Who approves a petrol pump layout plan?

PESO, the licensing authority, before building. It returns a signed copy of the plans if satisfied Petroleum Rules 2002, rule 131. Applications are made online in Form IX PESO FAQs on Petroleum Rules.

02Is there a standard petrol pump layout plan PDF?

Ask the oil company whether it has one. This guide gives no drawing; only the plan PESO approves for your site counts.

03What must the site plan show?

The surroundings and all protected works within 100 metres of the edge of the facilities to be licensed Petroleum Rules 2002, rule 131.

04Can I change the layout after it is approved?

Not before the licensing authority approves the altered drawing in writing Petroleum Rules 2002, rule 146; the licence must then be amended Petroleum Rules 2002, rule 146.

05Where is the licence number shown?

It must be prominently marked on the installation, shed or service station Petroleum Rules 2002, rule 133.

Related pages

Land needed for a petrol pump: size, lease and distance rulesHow much land a petrol pump needs, what a lease must say and which distance rules apply, from oil company guidelines, MoRTH, CPCB and PESO, checked on 9 November 2026.
Petrol pump land lease: what the lease must doWhat a land lease must show for a petrol pump: term, owners, papers PESO asks for, why a short lease is a risk, and when to ask an advocate. Checked 14 November 2026.
PESO licence for a petrol pump (Form XIV): steps and documentsHow a petrol pump gets its PESO licence in Form XIV under the Petroleum Rules 2002: the steps in order, documents, validity, renewal and fee, checked on 9 November 2026.
Underground tanks at a petrol pump: how they are built and testedHow a petrol pump's buried tanks are fitted, tested and checked for leaks under the Petroleum Rules 2002 and CPCB guidelines, with the vent, fill and dip pipes.

About Kavach Shuruaat (advertisement)

Planning a petrol pump? Kavach Shuruaat in the Dealer Kavach app answers your questions about opening one, from the official rule books, in Hindi or English, for ₹199 + GST a month. It explains the rules; the oil company decides who becomes a dealer.

About this page. This page is general information published by MDG Services, a brand of VRUOOM PRIVATE LIMITED (CIN U29194HR2021PTC098450), the company that makes Dealer Kavach. It is free to read and needs no sign-up.

We make an app for dealers. We make Dealer Kavach, an app for petrol pump dealers. Where a page mentions tools or services for a dealer, remember that. We state facts from the source, not our own opinion of what is best.

We do not sell dealerships or licences. MDG Services does not sell, allot, book or arrange petrol pump dealerships, land, licences or approvals, and we have no connection with any oil company's selection of dealers. Dealerships are offered only by the oil companies through their own advertisements and websites. The oil companies say no agent is authorised to ask candidates for money, and that fees and deposits are paid only through their official website. If someone asks you for money to get you a dealership, do not pay, and tell the oil company or the police.

Sources and dates. Every fact on these pages names its source: a law, a rule, a standard, a government notice or reply, or an oil company's own published guideline. Each page shows the date its facts were checked. Fees, figures, guidelines and portals change, and oil companies and states do not all follow the same rule. Check the source before you act, and tell us if anything here is out of date: we will correct it.

Not legal, tax or financial advice. Pages about licences, tax, fees or penalties explain the general position in India on the date shown. Laws and rules change, and every case is different. For your own case, speak to an advocate, a chartered accountant, or the oil company or authority concerned.

Earnings and costs are not promises. Nothing here promises a dealership, a licence, an income or a profit. Where a page gives a figure for a cost or a commission, it is what the source states on the date shown, not what any pump will earn or spend.

Other companies' names. Oil companies and every other company, product or body named here belong to their owners. We name them only to say whose rule or service a fact is about. They have not seen or approved these pages.

Report an error or send a legal notice. If you see a mistake, or need to send us a notice, write to hello@mdgservices.in. We read every message, check it, and correct or remove the page.

Limits on our responsibility. We take reasonable care to keep these pages accurate. To the extent the law allows, MDG Services and VRUOOM PRIVATE LIMITED are not responsible for loss caused by relying on this page alone. This does not limit anything the law does not allow us to limit, including responsibility for fraud or for an error we made after being told of it.

Advertisement. The box headed "About Kavach Shuruaat" at the end of a page, and the parts marked "Advertisement", are advertisements for Kavach Shuruaat, a service from MDG Services. Everything else on this page is free information.

Hindi pages. Hindi pages are written for easy reading and say the same as their English pages. Where a page mentions a law or a guideline, the official text is the one to follow.

Full disclaimer

Report an error or send a legal notice: hello@mdgservices.in